GE / IP FANUC Series 90/30 In Stock

Call Now

(919) 867-5794

Mon-Fri 8AM-5PM EST

509-EOD

✓ In Stock

Manufacturer: Allen Bradley - Miscellaneous
Product Type: Automation Product
Part Number: 509-EOD
Series: 509

Description:

The Allen-Bradley Bulletin 509 open-type full voltage starter 509-EOD is available as a component or as part of a modular kit. It has a nominal coil voltage of 110 to 120 volts. It has CSA, UL, and CE approvals.



Automation Stop is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with Automation Stop's 1-year warranty.

Refurbished

$1,775.00

Available: 13

What is Refurbished

Your order will ship by . Need it faster?

  Pay

We accept credit cards from all major providers, as well as PayPal.

  Ship

We offer worldwide shipping with UPS and DHL.

  Warranty

We proudly offer a one year Automation Stop warranty on most products.

The Allen-Bradley 509-EOD starter has a feed-through construction and it can be field wired for single or three-phase applications. It does not have any enclosure. The nominal coil voltage is 110 to 120 Volts with a frequency of 50/60 Hertz. The eutectic overload relay is CSA certified, UL listed, and complies with UL 508; it is CE marked. The continuous current rating is 135 Amperes and service limit current rating is 156 Amperes. The transformer primary switching kVA rating is 6.8 for inrush current, less than 20 times continuous current. For inrush current of 20 to 40 times continuous current, the rating is 3.4 Kilovolt-amperes. The circuit closing inrush current peak including offset for three phase is 1581 Amperes. The number of switching poles can vary from 2 to 5 with dimensions for width ranging from 7 to 10 and 7/16 inches (178 to 265.1 millimeters) and height of 12 11/64 inches (309 millimeters) and 7 13/16 inches (198.4 millimeters). The shipping weight varies from 22 to 28.5 pounds (10 to 13 kilograms). The wire size for power terminals is #6 to 4/0 AWG with required torque of 275 lb-in., and it has pressure terminals. The contact material is silver alloy for power contacts and silver for auxiliary contacts. The wire rating is 167 degrees Fahrenheit (75 degrees Celsius) or higher. The starter is mounted in vertical position and operates in the temperature range of -25 to 65 degrees Celsius (-13 to 149 degrees Fahrenheit). It can work at altitudes up to 10,000 feet before derating.

Technical Specifications

Product type Starter
NEMA size 4
NEMA enclosure None
Nominal coil voltage 110/120 Volts, 50/60 Hertz
Continuous current rating 135 Amperes
Service limit current rating 156 Amperes
Mechanical life 5 millions of operation
Max. number of aux. contacts 8 millions of operations
Pick-up time 27 ms avg.
Drop-out time 20 ms avg.
Wire size power terminals #6 to 4/0 AWG
Power contacts Silver alloy
We offer UPS shipping. Including Ground, 2nd Day Air, Next Day Air and Early AM. Some of our products have a short lead time, so please contact us if you need any item faster than the lead time shown. If you need to order an item internationally please contact us prior to checking out so we can get you a shipping quote. We can ship UPS or DHL internationally. We can also ship on your UPS or FedEx account number.
If the item is found to be defective within 30 days of the invoice date, a full refund can be issued. If an item is found to be defective through normal use and wear after 30 days but within the 1 year period, the Automation Stop Warranty dictates the appropriate course of action. After the 30 day period, Automation Stop reserves the right to decide between refund, repair, or replacement with identical product. Because of the high volume of outgoing and incoming shipments on a day to day basis, we unfortunately cannot accept returns on items ordered mistakenly or part numbers ordered incorrectly. If a special exception is approved, a 20% restocking fee will be assessed. If you have any questions please contact us at [email protected].

FAQ

Question: Does Automation Stop offer repairs on the 509-EOD?

Answer: Yes. We offer repairs for the 509-EOD and it comes with our 1 Year Automation Stop Warranty.


Question: What type of warranty comes with the Allen Bradley - Miscellaneous and 509-EOD?

Answer: If you buy the 509-EOD through Automationstop.com it comes with our 1 Year Warranty and no other warranties.


Question: Can I buy the 509-EOD online?

Answer: Yes. Automation Stop sells the 509-EOD online and you can check out for the quantity and condition listed available above.


Question: What is the manufacturer for the 509-EOD?

Answer: The 509-EOD is made by Allen Bradley - Miscellaneous.


Question: What is the Continuous current rating of the 509-EOD?

Answer: The Continuous current rating of the Rockwell Automation 509-EOD is 135 Amperes.


Question: What is the Drop-out time of the 509-EOD?

Answer: The Drop-out time of the Rockwell-Automation 509-EOD is 20 ms avg..


Question: What is the Max. number of aux. contacts of the 509-EOD?

Answer: The Allen Bradley/Rockwell Automation 509-EOD has a Max. number of aux. contacts of 8 millions of operations.


Question: What Mechanical life does the Allen Bradley-Rockwell Automation 509-EOD have?

Answer: The Allen Bradley-Rockwell Automation 509-EOD has a Mechanical life of 5 millions of operation.


Question: Does the Allen Bradley/Rockwell Automation 509-EOD have a NEMA enclosure?

Answer: None.


Question: What is the NEMA size of the 509-EOD?

Answer: The 509-EOD has a NEMA size of 4.


Question: What is the Nominal coil voltage of the Allen-Bradley 509-EOD?

Answer: The 509-EOD has a Nominal coil voltage of 110/120 Volts, 50/60 Hertz.


Question: What Pick-up time does the Allen Bradley/Rockwell Automation 509-EOD have?

Answer: The 509-EOD has a Pick-up time of 27 ms avg..


Question: What Power contacts are included with the 509-EOD?

Answer: The 509-EOD has Power contacts Silver alloy.


Question: What Product type is included with the 509-EOD?

Answer: The 509-EOD has a Starter Product type.


Question: What is the Service limit current rating of the 509-EOD?

Answer: The Service limit current rating of the Allen-Bradley 509-EOD is 156 Amperes.


Question: What is the Wire size power terminals of the 509-EOD?

Answer: The Wire size power terminals of the 509-EOD is #6 to 4/0 AWG.


Series information for 509-EOD

For additional information about 509-EOD check the data sheet or manual. Also check the manual PDF for all wiring diagrams, compatibility, troubleshooting, specifications, installation instructions, and accessories (such as batteries, terminal blocks, or cables) regarding 509-EOD.

Revision Part # Also Known As Availability
509-EOD/A 509-EOD Ser A, Series A, Rev A Request a Quote

Common Misspellings:

  • 509-E0D
  • 5O9-EOD
  • 5O9-E0D
  • S09-EOD
  • S09-E0D
  • SO9-EOD
  • SO9-E0D

Automation Stop sells used surplus products. Automation Stop is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by Automation Stop come with Automation Stop’s 1-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. Automation Stop is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Automation Stop is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Automation Stop also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Automation Stop also makes no representations as to your right to install any such firmware on the product. Automation Stop will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

TOP